當(dāng)前位置:天津天蝶閥門(mén)有限公司>>技術(shù)文章>>閥門(mén)電動(dòng)執(zhí)行器故障及解決方法
導(dǎo)讀:閥門(mén)電動(dòng)執(zhí)行器的電動(dòng)執(zhí)行器帶有極限終點(diǎn)限位開(kāi)關(guān),到終點(diǎn)能自動(dòng)切斷電路,同時(shí)為了保障工程安全,閥門(mén)電動(dòng)執(zhí)行器設(shè)有電力過(guò)載保護(hù)裝置和信號(hào)燈指示。
Introduction:The electric actuator of the valve electric actuator has the limit terminal limit switch, which can automatically cut off the circuit at the end. In order to ensure the safety of the project, the valve electric actuator is equipped with electric overload protection device and signal light indicator.
閥門(mén)電動(dòng)執(zhí)行器的故障分析
Failure analysis of valve electric actuator
閥門(mén)電動(dòng)執(zhí)行器安裝現(xiàn)場(chǎng)圖
Field diagram of valve electric actuator installation
閥門(mén)電動(dòng)執(zhí)行器可以分為電動(dòng)對(duì)夾式蝶閥和電動(dòng)法蘭式蝶閥,該類閥門(mén)是依靠電動(dòng)執(zhí)行器的電機(jī)工作,帶動(dòng)蝶閥的閥軸轉(zhuǎn)動(dòng),閥軸又帶動(dòng)蝶板旋轉(zhuǎn)90°來(lái)實(shí)現(xiàn)閥門(mén)的啟閉,可以做截?cái)嗪驼{(diào)節(jié)流量使用。閥門(mén)電動(dòng)執(zhí)行器的電動(dòng)執(zhí)行器帶有極限終點(diǎn)限位開(kāi)關(guān),到終點(diǎn)能自動(dòng)切斷電路,同時(shí)為了保障工程安全,閥門(mén)電動(dòng)執(zhí)行器設(shè)有電力過(guò)載保護(hù)裝置和信號(hào)燈指示。本文介紹閥門(mén)電動(dòng)執(zhí)行器可能出現(xiàn)的故障以及對(duì)應(yīng)的解決方法。
The valve electric actuator can be divided into electric pair clip butterfly valve and electric flange butterfly valve. This type of valve is based on electric actuator's motor to work, drives the valve shaft of butterfly valve to rotate, and the valve shaft drives the butterfly plate to rotate 90 degrees to realize the valve opening and closing, and can be truncated and adjusted the flow.The electric actuator of the valve electric actuator has the limit terminal limit switch, which can automatically cut off the circuit at the end. In order to ensure the safety of the project, the valve electric actuator is equipped with electric overload protection device and signal light indicator.This paper introduces the possible faults of valve electric actuator and the corresponding solutions.
故障1.閥門(mén)電動(dòng)執(zhí)行器閥門(mén)填料處外漏
Fault 1. leakage at the filling of the valve of the valve electric actuator
發(fā)生此類故障的原因有:①填料老化嚴(yán)重。②壓蓋螺栓沒(méi)有擰緊或出現(xiàn)松動(dòng)。
解決方法:①更換新的填料。②均勻的擰緊壓蓋螺栓。
The causes of such failures are:①The serious aging of fillers.② The gland bolt are not tightened or loosened.
Solutions:①u(mài)sing renewal fillers.②Tighten the cap bolt evenly.
故障2.端蓋出現(xiàn)滲漏
Fault 2.Leakage of end cover
發(fā)生此類故障的原因有:①螺栓未擰緊。②O型圈損壞。
the causes of such failures are:(1) the bolt is not tightened. (2) O type ring is damaged.
解決方法:①檢查螺栓是否松動(dòng),將其擰緊。②更換新的O型圈。
Solutions:①Check the loosening of the bolt and tighten it. ②use renewal O type ring.
故障3.密封面發(fā)生滲漏
Fault 3. Leakage of sealing surface
發(fā)生此類故障的原因有:①蝶板關(guān)閉不到位。②密封面存積污垢,導(dǎo)致關(guān)閉不嚴(yán)。③密封面損傷。
The causes of such failures are: ①the closure of the sphenoid plate is not in place. ②The sealing surface deposited dirt, which resulted in the lax closure. ③ the damage of the sealing surface.
解決方法:①調(diào)整閥門(mén)電動(dòng)執(zhí)行器電動(dòng)執(zhí)行機(jī)構(gòu)上的螺釘,將蝶板關(guān)閉到位。②清理密封面的存積污垢。③修補(bǔ)損傷的密封面。
Solutions:①adjust the screws on the electric actuator of the valve electric actuator and close the butterfly plate. ②Clean up the deposit and dirt of the sealing surface. ③ repair the damagedseal surface.
故障4.電動(dòng)裝置運(yùn)轉(zhuǎn)不靈活導(dǎo)致閥門(mén)不能正常啟閉
Fault 4.The operation of the electric device is not flexible, resulting in the valve can not normally open and close.
發(fā)生此類故障的原因有:①填料壓的過(guò)緊。②填料的壓蓋沒(méi)有緊固到位,發(fā)生傾斜。③過(guò)度裝置故障損壞。
The causes of such failures are:① the packing pressure is too tight.② The gland of the packing is not fastened in place and tilted. ③ fault damage of the overdevice.
解決方法:①填料壓蓋不要壓得過(guò)緊,適當(dāng)放松。②校正填料壓蓋的垂直度。③更換新的過(guò)渡裝置。
Solutions:① Packing gland should not be pressed too tightly, shoulid relax properly. ②Correct the perpendicularity of the packing gland. ③use renewal transition device.
故障5.啟閉到頭了電機(jī)沒(méi)?;蛘邌㈤]不*
Fault 5.The motor does not stop or the start and close are not complete
發(fā)生此類故障的原因有:①極限開(kāi)關(guān)失靈了或者是過(guò)載保護(hù)裝置不準(zhǔn)。②極限開(kāi)關(guān)動(dòng)作過(guò)早或反應(yīng)太遲。
The causes of such failures are:①The limit switch is out of order, or the overload protection device is not allowed. ②The limit switch works too early or too late.
解決方法:①更換極限開(kāi)關(guān)或者對(duì)過(guò)載裝置做調(diào)整,保證度。②調(diào)整極限開(kāi)關(guān)的反應(yīng)速度。
Solutions:①u(mài)se renewal limit switch or adjust the overload device to ensure accuracy. ②Adjust the reaction speed of the limit switch.