聯(lián)系我時,請告知來自 儀表網(wǎng)EAGLE 2 TEST Monitor up to 6 different autoranging gases PPM / LEL hydrocarbon detection PID (Photo Ionization Detector) low and high range for VOC detection Infrared Sensors available for CO2, %
EAGLE 2 Features Enclosure Weatherproof, chemical resistant, RFI / EMI coated high impact polycarbonate-PBT blend. Can operate in 2.0” of water without leakage. Ergonomically balanced with rugged top mounted handle. Water & dust resistant equivalent to IP65. Dimensions 9.5” L x 5.25” W x 5.875” H Weight 3.8 Lbs (standard 4 gas with batteries) Detection Principle Catalytic combustion, electrochemical cell, galvanic cell, infrared, photo ionization detector, and thermal conductivity. Sensor Life 2 Years under normal conditions. Sampling Method Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH Display 3 display modes: display all gases, large font-autoscroll, or large font-manual scroll. Polyurethane protected overlay. Backlight, illuminates for alarms and by demand with adjustable time. Language Readout can display in 5 languages (English, French, German, Italian, or Spanish. Alarms 2 Alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable. Alarm Method Buzzer 95 dB at 30 cm, four high intensity LED’s. Controls 4 External glove friendly push buttons for operation, demand zero, and autocalibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA/STEL values, battery status, conversion factors, and many other features. Continuous Operation At 70°F, 16 hours using alkaline batteries, or 20 hours using Ni-MH. Power Source 4 Alkaline or Ni-MH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines). Operating Temp. & Humidity -20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing. Indication Accuracy Maximum variance +/- 5% of full scale. Response Time 30 Seconds to 90% (for most gases) using standard 5 ft hose. Safety Rating Intrinsically Safe, Class I Approvals: CSA / CE Standard Accessories Shoulder strap, alkaline batteries, hydrophobic probe, and 5 foot hose, internal hydrophobic filter Optional Accessories Warranty Two year material and workmanship, one year for PID sensor RKI and TheHydrogenCompany.com are proud to offer the next generation of our popular EAGLE portable gas detector. Equipped with features that are not available on competitive units, the EAGLE 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. Detection combinations never before offered in a portable gas monitor are now available featuring the industry’s widest selection of high quality, long life and field proven sensors. The EAGLE 2 now includes PID (Photo Ionization Detector) capability. Conversion factors for a variety of common gases are programmed into the EAGLE 2 for both the PID sensor and LEL/PPM catalytic sensor. Made in U.S.A. Unique EAGLE 2 features include PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2, methane or hydrocarbons in LEL and % volume ranges; PID sensor for detecting high and low ppm levels (0-50 & 0-4,000) of VOC gases; methane elimination feature for environmental applications; and a list of super toxic gases and measurable ranges. The EAGLE 2 has a strong internal pump with a low flow auto pump shut off and alarm, which can draw samples from up to 125 feet. This allows for quick response and recovery from distant sampling locations. The EAGLE 2 will continuously operate for over 16 hours on alkaline batteries or 20 hours on Ni-MH. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, just to name a few. Datalogging is a standard feature for all sensors on all versions. Enclosure Weatherproof, chemical resistant, RFI / EMI coated high impact polycarbonate-PBT blend. Can operate in 2.0” of water without leakage. Ergonomically balanced with rugged top mounted handle. Water & dust resistant equivalent to IP65. Dimensions 9.5” L x 5.25” W x 5.875” H Weight 3.8 Lbs (standard 4 gas with batteries) Detection Principle Catalytic combustion, electrochemical cell, galvanic cell, infrared, photo ionization detector, and thermal conductivity. Sensor Life 2 Years under normal conditions. Sampling Method Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH Display 3 display modes: display all gases, large font-autoscroll, or large font-manual scroll. Polyurethane protected overlay. Backlight, illuminates for alarms and by demand with adjustable time. Language Readout can display in 5 languages (English, French, German, Italian, or Spanish. Alarms 2 Alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable. Alarm Method Buzzer 95 dB at 30 cm, four high intensity LED’s. Controls 4 External glove friendly push buttons for operation, demand zero, and autocalibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA/STEL values, battery status, conversion factors, and many other features. Continuous Operation At 70°F, 16 hours using alkaline batteries, or 20 hours using Ni-MH. Power Source 4 Alkaline or Ni-MH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines). Operating Temp. & Humidity -20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing. Indication Accuracy Maximum variance +/- 5% of full scale. Response Time 30 Seconds to 90% (for most gases) using standard 5 ft hose. Safety Rating Intrinsically Safe, Class I Approvals: CSA / CE Standard Accessories Shoulder strap, alkaline batteries, hydrophobic probe, and 5 foot hose, internal hydrophobic filter Optional Accessories Warranty Two year material and workmanship, one year for PID sensor Standard Confined Space Gases Hydrocarbons (CH4, std) 0 - 99% LEL 0 - 50,000 ppm Oxygen (O2) 0 - 40% Vol. Carbon Monoxide (CO) 0 - 500 ppm Hydrogen Sulfide (H2S) 0 - 100 ppm Toxics Ammonia (NH3) 0 - 75 ppm Arsine (AsH3) 0 - 1.5 ppm Chlorine (Cl2) 0 - 3 ppm Hydrogen Cyanide (HCN) 0 - 15 ppm Phosphine (PH3) 0 - 1 ppm Sulfur Dioxide (SO2) 0 - 6 ppm IR Sensors Carbon Dioxide (CO2) 0 - 10,000 ppm 0 - 5% Vol. 0 - 60% Vol. Methane (CH4) 0 - 99% LEL 0 - 99% Vol. Hydrocarbons 0 - 99% LEL PID Sensors VOC 0 - 2,000 ppm TC Sensors Methane (CH4) 0 - 99% Vol. Hydrogen (H2) 0 - 10% Vol. Adobe Acrobat Reader® required for viewing Introduction | Description | Operation EAGLE 2 PID Response Factors for VOCs Photoionization detectors are calibrated using isobutylene, but PID is a broadband VOC detection technique, with a sensitivity that differs for each VOC. If you know what VOC you are detecting, then the table below will allow you to calculate the concentration for your specific VOC. Remember, these are approximate values, so for best accuracy you should calibrate with the relevant VOC. Multiply the indicated concentration by the appropriate Relative Response value to provide an estimate of actual VOC concentration. Gas / VOC CAS No. Formula Relative With its ergonomic design and large glove friendly buttons, the EAGLE 2 offers easy access to controls such as autocalibration, alarm silence, demand zero, peak hold, methane elimination, and a wide variety of other features. Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are user adjustable and can be latching or self resetting. Rugged, reliable, easy to operate and maintain, the EAGLE 2 is the solution for just about any portable gas monitoring situation. Also, the display can be set to one of 5 languages: English, French, German, Italian, or Spanish.
Specification Information
Groups A, B, C, D.
Specifications subject to change without notice
EAGLE 2
Groups A, B, C, D.
Specifications subject to change without notice. Gases & Detectable Ranges
The EAGLE 2 can be configured with up to 6 gas sensors from the list below.
0 - 30% Vol.
0 - 50 ppm
0 - 99% Vol.
Specifications subject to change without notice. Special Features

EAGLE 2 Product Datatsheet

EAGLE 2 Brochure (6 pages)

Quick Reference Guide

EAGLE 2 Operator's Manual

EAGLE 2 Data Logger Management Program Operator's Manual

EAGLE 2 Maintenance Data Loader Operator's Manual
Calibration | Maintenance | Setup Mode | PID Sensor
This video is also available on Youtube and CD (by request)
Your browser does not support iframes. ![]()
![]()
![]()
![]()
Response
您感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN
儀表網(wǎng) 設計制作,未經(jīng)允許翻錄必究 .? ? ?
請輸入賬號
請輸入密碼
請輸驗證碼
請輸入你感興趣的產(chǎn)品
請簡單描述您的需求
號碼可能有誤,請核對!
請選擇省份
聯(lián)系方式
上海美盛自動化設備有限公司
桦甸市|
五台县|
枣强县|
沭阳县|
新宾|
南召县|
铁岭市|
晋宁县|
陇南市|
泗洪县|
扎赉特旗|
舟山市|
商河县|
鄢陵县|
濉溪县|
旺苍县|
安陆市|
黑龙江省|
墨脱县|
普兰县|
武功县|
临夏市|
玉田县|
申扎县|
慈利县|
体育|
上虞市|
朝阳区|
昭通市|
阿巴嘎旗|
元江|
阜康市|
齐河县|
巍山|
武隆县|
江津市|
桃江县|
前郭尔|
同江市|
遂宁市|
常州市|