珠海科邁爾儀器儀表有限公司
暫無信息 |
simpson 884-2 Sound Level Meters,Simpson's sound level meters come in two different versions to handle virtually any noise measurement requirement simpson 884-2 Sound Level Meters
simpson 884-2 Sound Level Meters,Simpson's sound level meters come in two different versions to handle virtually any noise measurement requirement simpson 884-2 Sound Level Meters
simpson 884-2 Sound Level Meters
Simpson's sound level meters come in twodifferent versions to handle virtually any noise measurementrequirement: the Model 884-2 with an "A" weighted scale for simplemeasurements and the Model 886-2 with a choice of fast or slowresponse and "A", "B" or "C" weighting. All three models haveoutput jacks for connecting to a Chart Recorder. Optionalcalibrators are available for in-field adjustment.
Sound Level Systems Simpson Type 2 sound level systems come in a variety of configurations to meet any noise measurement requirements. Each system is composed of several components designed to work together as one integrated test instrument and output jacks that will supply an AC RMS or DC Volt signal. • Meets IEC 651 and ANSI S1.4-1983 Meters • Meets OSHA and Walsh-Healy Noise Control Specifications • Quickly and Accurately Measures Sound Levels in Factories, Offices, Etc. • Full coverage 40-140 dB with special 85-115 dB OSHA range • Impact-resistant case contoured to minimize sound energy field reflections • Operates 40 hours on a 9V battery • AC and DC voltage jacks for recorder, analyzer and tester Interface • Built-in tripod mount The American National Standards Institute (ANSI) provides for three weighting curves: "A ", "B", and "C". The "A" weighted curve more closely corresponds to the response of the ear and is specified by OSHA. The "C" curve is essentially a “flat” frequency response and can be used in conjunction with a “fast response for an approximate indication of impulse noise levels. Low Frequency noises are better monitored by the “C” curve than the “A” curve. Low frequency sounds need to be louder to be heard. The chart below shows the relationship between frequency and relative response.
| 884-2 Sound Level Meter • Rugged solid-state reliability, • "A" weighting • Battery Operated
GENERAL Physical: 3.0" x 8.2" x 1.9" (77 x 208 x 47mm) Weight: 1.25 lbs (.57kg) Construction: Molded ABS Plastic Housing POWER REQUIREMENTS Battery type: (1) 9V NEDA 1604A Battery life: 40 hrs. (approx) TEMPERATURE RANGE Operating: -10° to 50°C Storage: -40° to 60°C Temp. influence: +/-0.015 dB/°C @ 1KHz Operating humidity: +/-0.5dB 0 to 90% SOUND LEVEL Ranges: 40 to 140 dB Reference: 0dB = 20m Pascals Accuracy: meets ANSI S1.4-1983 Weighting: 884-2 type S2A (only): "A" (external filter for flat response) 886-2 type 2 (only):A,B,C, (external filter for flat response) MICROPHONE Type: condenser type L size per ANSI S1.12-1967 Impedance: 350_ +/-20%@ 23°C Characteristics: omnidirectional, angle of incidence approximates random response equal to 70° SIGNAL OUTPUT External filter: 120mV RMS at meter reading of +10dB RMS Output: 1.00V RMS at meter reading of + 10dB dB Output: 1.5 VDC at meter reading of + 10dB Calibration: frequency=1000Hz @ 94dB on the 90 dB range, 114 dB on the 110 dB range. Screwdriver adjustable (from side of case) METER MOVEMENT Type: Pivot and Jewel, 2 1/2" dial; Scale: -10 to +10 dB w/(15) 1dB markings Accuracy: 2% Response time: Slow = 2.5 dB to a 500ms tone burst of 1000Hz Fast = 2.0 dB to a 200ms tone burst of 1000Hz OUTPUT JACK Type: Switchcraft # 750(0.141"dia.) f/external filter, # 850(0.097" dia.) f/dB and RMS output |
884-2&886-2 Datasheets |
您感興趣的產品PRODUCTS YOU ARE INTERESTED IN
商 鋪:珠海科邁爾儀器儀表有限公司 http://m.liuyangwu.com/st44722/
主營產品:simpson泄露電流測試儀,chatillon測力計,ED&D安規(guī)檢測,noiseken靜電設備,APC電源
移動端:珠海科邁爾儀器儀表有限公司手機站
儀表網 設計制作,未經允許翻錄必究 .? ? ?
請輸入賬號
請輸入密碼
請輸入你感興趣的產品
請簡單描述您的需求
號碼可能有誤,請核對!
請選擇省份
福鼎市|
东源县|
舞钢市|
绥滨县|
和平区|
淄博市|
墨玉县|
鹤岗市|
光山县|
亚东县|
漳浦县|
四川省|
阿巴嘎旗|
蒲江县|
拜城县|
新乐市|
长丰县|
张家港市|
荥经县|
玛多县|
扎囊县|
班戈县|
梓潼县|
娄底市|
长顺县|
寻乌县|
衡水市|
大化|
涡阳县|
积石山|
广宁县|
金乡县|
始兴县|
湘乡市|
镇沅|
监利县|
南和县|
禹城市|
民乐县|
无为县|
汝阳县|
