產(chǎn)品簡介

Maya2000 Pro Spectrometers are a great choice for applications requiring high sensitivity, good UV-NIR response and wide dynamic range. Applications range from low light level fluorescence and Raman m

詳細介紹

Maya2000 Pro Spectrometers are a great choice for applications requiring high sensitivity, good UV-NIR response and wide dynamic range. Applications range from low light level fluorescence and Raman measurements to absorbance, transmission and emission analysis of solutions, solids and gases.

At the heart of each Maya2000 Pro is a back-thinned 2D FFT-CCD detector – we offer two such detector options – in a robust, configurable optical bench with low-noise electronics and low-jitter triggering capabilities. Accessory and bench options allow users to optimize systems for setups ranging from the vacuum VUV (as low 165 nm) to the VIS-NIR (especially in the region <780 nm).

Maya2000 Pro Options at a Glance

Maya2000 Pro Spectrometers are versatile. If your application demands great response at lower wavelengths – especially <300 nm – the Hamamatsu S10420 detector version is your best bet.

For better sensitivity at longer wavelengths (>780 nm), we recommend the Hamamatsu S11510 detector version. Mix and match from a variety of gratings, slits and other accessories to maximize performance.

Also, we offer an application-ready Maya system that is a good option for Raman and low light level applications where long integration times are not necessary. The Maya2000 Pro-NIR, is preconfigured with the S11510 detector, is optimized to 780-1180 nm and includes a longpass filter, 50 μm slit and gold mirrors for enhanced NIR sensitivity.


Application Criteria

Recommended Detector

Sample Applications


VUV measurements (<~190 nm)*

Hamamatsu S01420

·         Analysis of VUV emission sources

·         Determination of plasmas used in semiconductor processing



UV-Vis measurements (~190-600 nm)

Hamamatsu S01420

·         UV absorbance of plasmas and gases

·         Low light level applications such as fluorescence


 * For VUV applications, you will need a MAYA-DEEP-UV window for the spectrometer. Learn more about purging and other VUV setup requirements here.


Application Criteria

Recommended Detector

Sample Applications


Vis-NIR measurements (~800-1100 nm)

Hamamatsu S11510 in modular Maya2000 Pro

·         Raman 

·         Low light level VIS-NIR experiments

·         SW-IR feasibility studies of various samples



Comparing Maya2000 Pro Options

Maya2000 Pro Detector Response Only

Here is spectral response data that Hamamatsu reports for its S10420 and S11510 FFT-CCD image sensors. Detector response represents just one element of spectrometer system response. System response combines the effects of all the elements of the instrument, including the optical bench design and grating choice.

Maya2000 Pro System Response Spectra

This graph shows the spectral response of Maya2000 Pro spectrometers configured with both UV-VIS (S10420) and VIS-NIR (S11510) back-thinned CCD detectors. Also, the graph includes spectral response of our USB2000+XR1, which has a front-illuminated CCD detector.

In this setup, we measured the relative output of a miniature deuterium tungsten halogen source. A trifurcated optical fiber transmitted signal to the spectrometers, which were set to different integration times to keep within scale. Also, the Maya2000 Pro with S11510 detector required attenuation at the fiber to avoid saturation.

Specifications


Physical

Maya2000 Pro

Dimensions (mm):

182 x 110 x 47

Weight:

1.18 kg (2.6 lb.)

Detectors


Type:

Back-thinned, 2D

Options:

Hamamatsu S10420 (best option for UV-Vis applications)

Hamamatsu S11510 (best option for Vis-NIR applications)

Quantum efficiency:

75% peak @ 600 nm  (S10420)

85% peak @ 700 nm (S11510)

Spectroscopic


Spectral range (detector response):

~165-1100 nm (S10420)

~400-1180 nm (S11510)

Optical resolution (FWHM):

Depends on grating groove density and slit size (multiple options available)

Signal-to-noise ratio at full signal:

~450:1

Dynamic range:

15000:1 (typical)

Integration time:

7.2 ms-5 seconds

Fiber optic connector:

SMA 905 to 0.22 numerical aperture single-strand optical fiber

Electronics


Power requirement:

500 mA @ +5 VDC

Trigger modes:

4 modes

Strobe functions:

Yes

Interfaces:

USB 2.0, RS-232

Environmental Conditions


Temperature:

0 °C to +50 °C (operation)

Humidity:

0-90% non-condensing


Sample Maya2000 Pro Applications

At Our Applications Blog

  • Testing the Stability of Polymeric Semiconductor Materials
  • Raman Analysis of Diesel Fuel using the Maya2000 Pro-NIR

References

This is a small sampling of the many Maya2000 Pro technical citations available. Where possible, we’ve listed citations available freely. In some cases, free access carries certain stipulations imposed by the publisher or author, so please be certain to follow proper protocols.

Absorbance/Transmission

  • Lei Zhang, Pan Wang, Yao Xiao, Huakang Yu and Limin Tong. Ultra-sensitive microfibre absorption detection in a microfluidic chip. Lab on a Chip, Issue 21, 2011.
  • Holger Hintz, J.-J. Egelhaaf, Larry Lüer, Jens Hauch, Heiko Peisert and Thomas Chasse. Photodegradation of P3HT – A Systematic Study of Environmental Factors. Chemistry of Materials, 2011, 23, 145-154.
  • Ben Azouz, Aymen and Karazi, Shadi and Brabazon, Dermot and Vázques, Mercedes and Macka, Mirek and Paull, Brett (2010). Effect of laser processing parameters and glass type on topology of micro-channels. In: Microtech 2010 Conference & Expo, 21-24 June 2010, Anaheim, CA, USA.

Emission

  • &#8226; Zhai Tian-Rui, Zhang Xin-Ping, Diu Fci. Microscopic Investigation into the Optically Pumped Polymer Lasers Based on Distributed Feedback. China Physics Letters, Vol. 29, No, 10 (2012)
  • S.F. Mikhailov, J.Y. Li, V.G. Popov, P.W. Wallace, Y.K. Wu. Soft Orbit Bump for Duke Storage Ring VUV FEL Operation. FEL Laboratory/TUNL and Dept. of Physics, Duke University, Durham, N.C.
  • Yan Wang, Shihao Liu, Fangyuan Dang, Yang Li, Yongming Yin, Jian Liu, Kai Xu, Xuecheng Piao and Wenfa Xie.. An efficient flexible white organic light-emitting device with a screen-printed conducting polymer anode. Journal of Physics D: Applied Physics Volume 45 Number 40.

Reflectance

  • Scott Noble, Dali Li. Segmentation of Greenhouse Cucumber Plants in Multi-Spectral Imagery. Department of Chemical and Biological Engineering, University of Saskatchewan, 2012.
  • K.N. Nguyen, D. Abi-Saab, P. Basser, E. Richalot, F. Marty, D. Angelescu, Y. Leprince-Wang, T. Bourouina. Black Silicon with Sub-percent Reflectivity: Influence of the 3D Texturization Geometry. Transducers ’11, Beijing, China, June 5-9, 2011.

Yongchun Lu, Yanhong Lin, Dejun Wang, Lingling Wang, Tengfeng Xie, Tengfei Jiang. Surface charge transfer properties of high-performance Ag-decorated ZnO photocatalysts. Journal of Physics D: Applied Physics, Volume 44, Number 31, 15 July 2011.

其他推薦產(chǎn)品更多>>

您感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN

儀表網(wǎng) 設計制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://m.liuyangwu.com,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責,儀表網(wǎng)對此不承擔任何保證責任。 溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務必確認供應商資質(zhì)及產(chǎn)品質(zhì)量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

請 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~
宁武县| 昭觉县| 黔东| 广南县| 德格县| 策勒县| 盐源县| 曲阜市| 武胜县| 蚌埠市| 陇川县| 睢宁县| 商丘市| 乌兰县| 乐业县| 长白| 个旧市| 拜泉县| 吉水县| 竹北市| 铅山县| 确山县| 宜川县| 榕江县| 阳新县| 临武县| 乳山市| 高邮市| 东乡| 同德县| 黔南| 古浪县| 阳山县| 白山市| 扶余县| 饶阳县| 从江县| 洞头县| 江达县| 永德县| 新巴尔虎左旗|