當前位置:安捷來國際股份(香港)有限公司>>德國Nabertherm高溫爐>>*材料>> HT 64/16 LB, LT HT 64/17 LB,High-Temperature Furnaces up to 1800 °C
| 參 考 價 | 面議 |
產(chǎn)品型號HT 64/16 LB, LT HT 64/17 LB,
品 牌
廠商性質(zhì)經(jīng)銷商
所 在 地
聯(lián)系方式:銷售查看聯(lián)系方式
更新時間:2023-04-18 07:54:40瀏覽次數(shù):454次
聯(lián)系我時,請告知來自 儀表網(wǎng)Dewaxing Furnaces, Electrically Hea
Furnaces with Radiation Heating up
High-Temperature Furnaces up to 180
| HT 276/17 LT HDB with manual table changing system and Debinding Package II | HT 276/18 LTS with two ceramic retorts for sintering under protective gas |
HT 64/17 LT
HT 680/17 LTS2 with table exchange system
All-round heating of the hood by means of molybdenum disilicide heating elements
High-temperature furnace HT 273/17S with table by transportable fork lift
For charging complex settings we recommend lift-top or lift-bottom furnaces.
Also small workparts can be conveniently loaded on different layers. Up to an
application temperature of 1500 °C the furnaces are heated by SiC rods (HTC models).
For sintering temperatures above 1500 °C these furnaces with molybdenum disilicide
heating elements (HT models). Possible potential chemical interaction between the
charge and the heating method can also affect the selection of heating system.
The basic furnace comes with one table. Depending on the technical requirements
are equipped, a lift-top or lift-bottom version will be the choice. The system can be
expanded with one or more changeable tables, either manually or electrically driven.
Other additional equipment, like controlled cooling systems to short process cycles
or the addition of a debinding package for debinding and sintering in
one process provide for tailored solution for individual needs.
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions in mm | Supply | Electrical | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | w | d | h | in l | W | D | H | power/kW | connection* | in kg | |
| HT 64/16 LB, LT | 1600 | 400 | 400 | 400 | 64 | 950 | 1100 | 2350 | 36 | three-phase | 480 |
| HT 166/16 LB, LT | 1600 | 550 | 550 | 550 | 166 | 1100 | 1250 | 2500 | 42 | three-phase | 1100 |
| HT 276/16 LB, LT | 1600 | 1000 | 500 | 550 | 276 | 2000 | 1400 | 2500 | 50 | three-phase | 1200 |
| HT 400/16 LB, LT | 1600 | 1200 | 600 | 550 | 400 | 2200 | 1500 | 2500 | 72 | three-phase | 1300 |
| HT 1000/16 LB, LT | 1600 | 1000 | 1000 | 1000 | 1000 | 1600 | 2100 | 2800 | 146 | three-phase | 1500 |
| HT 1010/16 LB, LT | 1600 | 2150 | 600 | 800 | 1032 | 3200 | 1300 | 3400 | 156 | three-phase | 2000 |
| HT 1440/16 LB, LT | 1600 | three-phase | |||||||||
| HT 64/17 LB, LT | 1750 | 400 | 400 | 400 | 64 | 950 | 1100 | 2350 | 36 | three-phase | 480 |
| HT 166/17 LB, LT | 1750 | 550 | 550 | 550 | 166 | 1100 | 1250 | 2500 | 42 | three-phase | 1100 |
| HT 276/17 LB, LT | 1750 | 1000 | 500 | 550 | 276 | 2000 | 1400 | 2500 | 50 | three-phase | 1200 |
| HT 400/17 LB, LT | 1750 | 1200 | 600 | 550 | 400 | 2200 | 1500 | 2500 | 72 | three-phase | 1300 |
| HT 1000/17 LB, LT | 1750 | 1000 | 1000 | 1000 | 1000 | 1600 | 2100 | 2800 | 146 | three-phase | 1500 |
| HT 1010/17 LB, LT | 1750 | 2150 | 600 | 800 | 1032 | 3200 | 1300 | 3400 | 156 | three-phase | 2000 |
| HT 1440/17 LB, LT | 1750 | three-phase | |||||||||
| HT 64/18 LB, LT | 1800 | 400 | 400 | 400 | 64 | 950 | 1100 | 2350 | on request | three-phase | 480 |
| HT 166/18 LB, LT | 1800 | 550 | 550 | 550 | 166 | 1100 | 1250 | 2500 | on request | three-phase | 1100 |
| HT 276/18 LB, LT | 1800 | 1000 | 500 | 550 | 276 | 2000 | 1400 | 2500 | on request | three-phase | 1200 |
| HT 400/18 LB, LT | 1800 | 1200 | 600 | 550 | 400 | 2200 | 1500 | 2500 | on request | three-phase | 1300 |
| HT 1000/18 LB, LT | 1800 | 1000 | 1000 | 1000 | 1000 | 1600 | 2100 | 2800 | on request | three-phase | 1500 |
| HT 1010/18 LB, LT | 1800 | 2150 | 600 | 800 | 1032 | 3200 | 1300 | 3400 | on request | three-phase | 2000 |
| HT 1440/18 LB, LT | 1800 | 1800 | 800 | 1000 | 1440 | 2300 | 2900 | 3700 | 280 | three-phase | 2500 |
| *Please see page 70 for more information about mains voltage ¹All dimensions without transformer housing, without hydraulic unit, and without switchgear cabinet | |||||||||||
索取資料
打印版本
| HT 16/16 | HT 160/17 with catalytic afterburning system |
HT 128/17 S with lift door for opening in hot state
Protection of heating elements against mechanical damage
Fresh air injection through perforated injection tubes with Debinding Package II
Display of pressure and volume flow with Debinding Package II
Retort with gas injection through the furnace bottom protects the furnace chamber against
contamination and/or prevents chemical interaction between the charge and heating elements
Gas supply system for protective gases
The high-temperature chamber furnaces HT 04/16 - HT 450/18 have proven reliable over
many years in the lab and in the production of technical ceramics. Whether for bioceramics,
for sintering CIM components or for other processes up to a maximum temperature of 1800 °C,
these furnaces afford the optimal solution for the sintering process.
High-temperature chamber furnaces can either be insulated with fiber material or lightweight
refractory bricks. Furnaces with fiber insulation achieve significantly shorter heating up times
because of the low thermal mass. An insulation made of lightweight refractory bricks
(see HFL models on page 33), on the other hand, has the advantage of better chemical stability.
These furnaces can also be tailored to specific processes by means of a wide range of
additional equipment. The addition of a debinding package, for example, allows the use of
these models as combi furnaces for debinding and sintering in one process.
Thermal or catalytic exhaust cleaning equipment round up the system.
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions in mm | Supply | Electrical | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | w | d | h | in l | W | D | H | power/kW | connection* | in kg | |
| HT 04/16 | 1600 | 150 | 150 | 150 | 4 | 610 | 470 | 1400 | 5.2 | three-phase¹ | 150 |
| HT 08/16 | 1600 | 150 | 300 | 150 | 8 | 610 | 610 | 1400 | 8.0 | three-phase¹ | 200 |
| HT 16/16 | 1600 | 200 | 300 | 260 | 16 | 710 | 650 | 1500 | 12.0 | three-phase¹ | 270 |
| HT 32/16 | 1600 | 200 | 600 | 260 | 32 | 710 | 930 | 1500 | 18.0 | three-phase | 350 |
| HT 40/16 | 1600 | 300 | 350 | 350 | 40 | 810 | 710 | 1610 | 12.0 | three-phase | 380 |
| HT 64/16 | 1600 | 400 | 400 | 400 | 64 | 1020 | 840 | 1700 | 18.0 | three-phase | 550 |
| HT 128/16 | 1600 | 400 | 800 | 400 | 128 | 1020 | 1250 | 1700 | 26.0 | three-phase | 750 |
| HT 160/16 | 1600 | 500 | 550 | 550 | 160 | 1140 | 1020 | 1900 | 21.0 | three-phase | 800 |
| HT 276/16 | 1600 | 500 | 1000 | 550 | 276 | 1140 | 1470 | 1900 | 36.0 | three-phase | 1100 |
| HT 450/16 | 1600 | 500 | 1150 | 780 | 450 | 1140 | 1620 | 2060 | 64.0 | three-phase | 1500 |
| HT 04/17 | 1750 | 150 | 150 | 150 | 4 | 610 | 470 | 1400 | 5.2 | three-phase¹ | 150 |
| HT 08/17 | 1750 | 150 | 300 | 150 | 8 | 610 | 610 | 1400 | 8.0 | three-phase¹ | 200 |
| HT 16/17 | 1750 | 200 | 300 | 260 | 16 | 710 | 650 | 1500 | 12.0 | three-phase¹ | 270 |
| HT 32/17 | 1750 | 200 | 600 | 260 | 32 | 710 | 930 | 1500 | 18.0 | three-phase | 350 |
| HT 40/17 | 1750 | 300 | 350 | 350 | 40 | 810 | 710 | 1610 | 12.0 | three-phase | 380 |
| HT 64/17 | 1750 | 400 | 400 | 400 | 64 | 1020 | 840 | 1700 | 18.0 | three-phase | 550 |
| HT 128/17 | 1750 | 400 | 800 | 400 | 128 | 1020 | 1250 | 1700 | 26.0 | three-phase | 750 |
| HT 160/17 | 1750 | 500 | 550 | 550 | 160 | 1140 | 1020 | 1900 | 21.0 | three-phase | 800 |
| HT 276/17 | 1750 | 500 | 1000 | 550 | 276 | 1140 | 1470 | 1900 | 36.0 | three-phase | 1100 |
| HT 450/17 | 1750 | 500 | 1150 | 780 | 450 | 1140 | 1620 | 2060 | 64.0 | three-phase | 1500 |
| HT 04/18 | 1800 | 150 | 150 | 150 | 4 | 610 | 470 | 1400 | 5.2 | three-phase¹ | 150 |
| HT 08/18 | 1800 | 150 | 300 | 150 | 8 | 610 | 610 | 1400 | 9.0 | three-phase¹ | 200 |
| HT 16/18 | 1800 | 200 | 300 | 260 | 16 | 710 | 650 | 1500 | 12.0 | three-phase¹ | 270 |
| HT 32/18 | 1800 | 200 | 600 | 260 | 32 | 710 | 930 | 1500 | 18.0 | three-phase | 350 |
| HT 40/18 | 1800 | 300 | 350 | 350 | 40 | 810 | 710 | 1610 | 12.0 | three-phase | 380 |
| HT 64/18 | 1800 | 400 | 400 | 400 | 64 | 1020 | 840 | 1700 | 18.0 | three-phase | 550 |
| HT 128/18 | 1800 | 400 | 800 | 400 | 128 | 1020 | 1250 | 1700 | 26.0 | three-phase | 750 |
| HT 160/18 | 1800 | 500 | 550 | 550 | 160 | 1140 | 1020 | 1900 | 21.0 | three-phase | 800 |
| HT 276/18 | 1800 | 500 | 1000 | 550 | 276 | 1140 | 1470 | 1900 | 36.0 | three-phase | 1100 |
| HT 450/18 | 1800 | 500 | 1150 | 780 | 450 | 1140 | 1620 | 2060 | 64.0 | three-phase | 1500 |
| ¹Only heating between two phases *Please see page 70 for more information about mains voltage | |||||||||||
索取資料
打印版本
| HFL 160/17 with gas supply system | HFL 295/13 with lift door and transformer in stand, customer-specific design |
Gas supply system for HFL 160/17
Protection grid in front of heating elements prevent against mechanical damages
The HFL 16/16 HFL 160/17 product line is characterized by its lining with robust light weight
refractory bricks. Compared with the fiber-insulated models of the HT product line, these
furnaces are recommended when high charge weights have to be sintered. In most cases
lightweight refractory brick insulation is also significantly more resistant to gas emissions occurring during heat treatment.
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions in mm | Supply | Electrical | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | w | d | h | in l | W | D | H | power/kW | connection* | in kg | |
| HFL 16/16 | 1600 | 200 | 300 | 260 | 16 | 770 | 830 | 1550 | 12 | three-phase¹ | 500 |
| HFL 40/16 | 1600 | 300 | 350 | 350 | 40 | 880 | 880 | 1710 | 12 | three-phase | 660 |
| HFL 64/16 | 1600 | 400 | 400 | 400 | 64 | 980 | 930 | 1830 | 18 | three-phase | 880 |
| HFL 160/16 | 1600 | 500 | 550 | 550 | 160 | 1090 | 1080 | 2030 | 21 | three-phase | 1140 |
| HFL 16/17 | 1700 | 200 | 300 | 260 | 16 | 770 | 830 | 1550 | 12 | three-phase¹ | 530 |
| HFL 40/17 | 1700 | 300 | 350 | 350 | 40 | 880 | 880 | 1710 | 12 | three-phase | 690 |
| HFL 64/17 | 1700 | 400 | 400 | 400 | 64 | 980 | 930 | 1830 | 18 | three-phase | 920 |
| HFL 160/17 | 1700 | 500 | 550 | 550 | 160 | 1090 | 1080 | 2030 | 21 | three-phase | 1190 |
| ¹Only heating between two phases *Please see page 70 for more information about mains voltage | |||||||||||
索取資料
打印版本
| HTB 645/17 |
The gas-fired high-temperature furnaces of the HTB product line are specially developed for
applications requiring fast heating up ramps. Gas-fired furnaces are preferred also if inflammable
gases are produced in large amounts during the process. A large content of the gas emissions are
already burned in the furnace chamber, so that downstream equipment like thermal and catalytic
exhaust cleaners can accordingly be downsized. The furnaces are insulated with highly heat-resistant
and long-life lightweight refractory brick insulation or fiber materials.
請輸入賬號
請輸入密碼
請輸驗證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關企業(yè)負責,儀表網(wǎng)對此不承擔任何保證責任。