Measured Point-to-Point Mechanical Resolution per Adjuster
5 µrad (Typical); 2 µrad (Achievable)
Measured Adjuster Lock Mechanical Resolution per Adjusterc
5 µrad (Typical); 2 µrad (Achievable)
Resolutiond
~7.7 mrad/rev
Front Plate Translation (Max)
6 mm
N/A
Mechanical Angular Range (Nominal)
±4°
Beam Deviation After Thermal Cycling
< 1 µrade
Recommended Turns Backf
1.25
Mountingg
Two #8 (M4) Counterbores
Alignment Pin Holesh
Two at Each Counterbore
Vacuum Compatibilityi
10-9 Torr at 25 °C with Proper Bake Out; 10-5 Torr at 25 °C without Bake Out Grease Vapor Pressure: 10-13 Torr at 20 °C ,10-5 Torr at 200 °C Epoxy Meets Low Outgassing Standards NASA ASTM E595, Telcordia GR-1221
Operating Temperature Range
-30 to 200 °C
a. 為了獲得*佳性能,請(qǐng)使用直徑公差*多為+0/-0.005英寸的光學(xué)元件。
b. 使用附帶的光學(xué)元件固定彈簧和卡環(huán)安裝時(shí)的數(shù)值。
c. 使用POLARIS®鎖定螺母時(shí)的數(shù)值。
d. 當(dāng)前板和后板平行時(shí)。
e. 對(duì)于安裝在?1英寸接桿上的Polaris調(diào)整架且光束高度為2英寸時(shí),經(jīng)12.5 °C溫度循環(huán)后,光束回到原始位置的1 μrad內(nèi)。詳情請(qǐng)查看測(cè)試數(shù)據(jù)標(biāo)簽。
f. 有關(guān)光學(xué)元件安裝的詳情,請(qǐng)查看光學(xué)元件安裝標(biāo)簽。
g. ?1英寸調(diào)整架帶有8-32和M4帶帽螺絲。
h. 我們推薦標(biāo)準(zhǔn)的DIN 7-m6定位銷。匹配定位銷孔和螺紋安裝孔的推薦公差是±0.003英寸。
i. 這些調(diào)整架都是真空兼容的,且在潔凈環(huán)境下裝配,使用Carpenter A/A/A鈍化方法進(jìn)行化學(xué)清潔以除去表面硫、鐵以及污染物,*后經(jīng)過雙層真空包裝。Polaris調(diào)整架附帶的8-32和M4固定螺絲的額定壓力不能低于10-5 Torr。將任何組件放進(jìn)靈敏的真空系統(tǒng)中前,需要在烘烤爐中進(jìn)行全面的預(yù)烘烤以除去shi氣和表面揮發(fā)性物質(zhì)。詳細(xì)信息,請(qǐng)聯(lián)系我們。