| 類型 | 代號 | 測量范圍℃ | 精度等級 | 允許偏差Δt℃ |
| K 鎳鉻,熱電偶 | WRN | 0-800 | I | *±1.5℃or±0.4%t |
| II | *±2.5℃or±0.75%t | |||
| E 鎳鉻-銅鎳 | WRE | 0-600 | I | *±1.5℃or±0.4%t |
| II | *±2.5℃or±0.75%t | |||
| J 鐵-銅鎳 | WRJ | 0-500 | I | *±1.5℃or±0.4%t |
| II | *±2.5℃or±0.75%t | |||
| T 銅-銅鎳 | WRT | -40- +350 | I | *±0.5℃or±0.4%t |
| II | *±1℃or±0.75%t | |||
| S | WRP | 0-1600 | II | ±1.5℃ or ±0.25%t |
| 鉑電阻 Pt10或裝Pt100 | WZP | -200- +850 | A | -200- +650 ±(0.15+0.002 ltl) |
| B | -200- +850 ±(0.30+0.005 ltl) |
| 溫度等級 | 允許高表面溫度℃ |
| T1 | 450 |
| T2 | 300 |
| T3 | 200 |
| T4 | 135 |
| T5 | 100 |
| T6 | 85 |
| 溫度傳感器類型 | 分度號 | 推薦測量范圍(℃) |
| 熱電偶 | B | 600-1600 800-1600 900-1800 1000-1600 1000-1800 |
| S | 0-1300 0-1600 400-1600 600-1600 800-1400 800-1600 900-1400 1000-1400 | |
| K | 0-300 0-600 0-800 0-1000 0-1300 400-800 400-1300 600-1300 | |
| E | 0-200 0-400 0-800 0-600 200-600 300-500 400-600 | |
| J | 0-200 0-400 0-600 300-600 | |
| T | -200-0 –200-300 0-200 0-300 | |
| 鉑熱電阻 | Pt100 | -200-+50 –100-50 –50-+50 –50-+100 0-50 0-100 0-150 0-200 0-300 0-400 0-500 200-400 200-500 |
| Pt10 | 0-150 0-200 0-300 0-500 0-700 0-850 50-100 200-400 –50-+50 | |
| 銅熱電阻 | Cu50 | -50-+50 –50-+100 –50-+150 0-50 0-100 0-150 |
| 故障現(xiàn)象 | 可能原因 | 修理方法 |
| 顯示儀表指示值比實際值低或指示值不穩(wěn)定。 | 保護管或接線盒內(nèi)有水,金屬屑、灰塵或熱電阻短路。 | 1、倒出水或消除灰塵,并將潮濕部分加以干燥處理,(不得用火烤),提高絕緣性。 2、用萬用表檢查短路或接地線部分,并消除之。如系感溫元件短路,應進行修復或更換。 |
| 顯示儀表指示值無限大 | 熱電阻斷路 | 1、用萬用表檢查斷路部分,確定是連接導線還是感溫元件斷路。 2、如系連接導線斷路,可以更換或修復。 3、如系感溫元件斷路,應進行更換。 |
| 顯示儀表指針反向標尺下限值 | 1、熱電阻短路。 2、與顯示儀表接線接錯 | 1、用萬用表確定短路部位,并消除之,如系感溫元件短路,應進行修復或更換。 2、重新連接導線 |